What scale does
Municipal water carries dissolved minerals. As the machine freezes water, those minerals concentrate and deposit on the evaporator and in the water circuit. The layer insulates the surface the ice forms on, so each cycle takes longer and produces less.
Early on you notice cloudy or soft cubes. Later, production drops and the bin empties before service ends. Left long enough, the evaporator is damaged and the repair is no longer a service.
Filtration and descaling
A filter removes the solids before they reach the machine, and a descale dissolves what has already built up. Both are needed: filtration alone does not clean a scaled circuit, and descaling alone does not stop it coming back.
For a busy machine on Cape water, a descale every three to six months is realistic. A lightly used home bar can go longer. The right interval depends on how hard the machine works, not on a fixed calendar.
The other half of the job
Airflow and ambient temperature matter as much as water. A machine in a hot back room with a dusty condenser will underperform even when the water side is perfect, because it cannot reject heat.
Bin insulation and door seals decide how long the ice lasts once it is made. Those are cheap items and they are the difference between a bin that holds through service and one that turns to slush.
In short
- Scale slows production long before it stops the machine.
- Filtration prevents, descaling corrects: you need both.
- Hot, dusty positions and poor bin seals waste good ice.