Commercial
Freezer Room Installation & Repairs
A freezer room is unforgiving. A chiller that drifts by three degrees costs you quality; a freezer room that fails overnight costs you the load, and possibly the week.
We install and repair freezer rooms for butcheries, caterers, takeaways and small food producers, typically running at -18 °C to -22 °C, with blast capacity where product arrives warm. Below zero the details matter more than in a chiller: a heated drain that stops working freezes solid, a defrost termination that ends early leaves ice on the coil, and a door heater that has failed welds the door shut.
On existing rooms, our first job is usually to work out what is actually wrong rather than what it feels like. A room that is slow to recover in the afternoon may have a door left open during deliveries, a torn seal, or a condenser sitting in a hot, enclosed yard. We measure the room's performance before recommending a bigger unit, because half the freezer rooms we are called to are working against a door or a plant position rather than a capacity problem.
Heated drains and door frames
Below zero, water management is the whole game. Drain heating and door frame heating are specified in, not added after the first flood.
Defrost that completes
The difference between a clean coil and a solid block of ice is usually termination settings and a probe in the right place.
Alarms and logging
For a room holding a week of stock, an alarm that reaches a phone is worth more than extra capacity you never needed.
What the work includes
- Freezer room design, panels and heavy door installation
- Condensing unit and evaporator supply and repair
- Heated drain, drain line and door frame repair
- Defrost controls, termination and probe replacement
- Temperature alarms, monitoring and logging
- Panel damage, seal and hinge repair on existing rooms
When to call us
- The room is not reaching temperature after deliveries
- Ice building up on the coil or the floor
- The door is hard to open or will not close fully
- Water or ice under the evaporator
- The unit runs flat out and never cuts out
Questions
Freezer rooms, answered
How cold should a freezer room be?
Around -18 °C to -22 °C for frozen storage, with colder blast capacity if you are freezing warm product. The right figure depends on what you store and for how long.
Can a cold room be converted into a freezer room?
Sometimes. It depends on the panel thickness, the door, the drain heating and the equipment. We assess the envelope honestly rather than promising a conversion that will ice up.
Why does the floor ice up around the door?
Usually a failed door or frame heater, or a seal that lets moist air in. Both need fixing before the ice becomes a safety problem.
Do you stock spare panels and doors?
Common panel sizes and hardware, yes. Anything unusual we source, and we will tell you the lead time before you commit so you can plan around the room being down.
Related services
Cold Room Installation & Repairs
Walk-in chillers designed, built, repaired and serviced, from a small back-room unit to a full commercial room.
Read moreCommercial Refrigeration
Display fridges, prep counters, under-bar units and bottle coolers kept running for takeaways, butcheries, cafés and home businesses.
Read moreChiller Installation & Maintenance
Air-cooled and process chillers installed, repaired and kept on a schedule, so a building or a production line stays cool.
Read moreEdgemead, Monte Vista & Bothasig
Tell us what is happening in the room.
A call or a WhatsApp message with the symptom and the address is usually enough for us to tell you what kind of visit this is.