Floor area is only the starting point
The rule of thumb that circulates online gives you a number based on square metres. It is a starting point at best. The same room facing west with a large unshaded window can need a size up from one facing south, because the heat coming through glass in the late afternoon is far greater than the heat coming through a well-insulated wall.
Ceiling height, insulation and how many people use the room all shift the number too. A room under a hot tile roof with no ceiling insulation is a different proposition from one with a cool ceiling cavity above it.
Oversizing is a real fault, not a safety margin
A unit that is too large cools the air quickly, switches off before it has removed much moisture, and then switches on again. The room feels cold and clammy, the compressor cycles constantly, and the unit wears out sooner. In a bedroom, the noise of that cycling is often the thing people notice most.
An undersized unit has the opposite problem: it runs flat out, never quite reaches setpoint on a hot night, and never gets a rest either. Neither is a good outcome, which is why measuring beats guessing.
Where the unit goes matters as much as its size
An indoor unit blowing directly onto a bed is uncomfortable at any capacity. High on a wall, with the louvres set to throw air along the ceiling rather than down at the sleeper, works far better. The outdoor unit needs air on both sides, clearance from the wall, and a position that is not directly outside the window it is cooling.
In the older, denser parts of Monte Vista, the outdoor position is usually the hardest decision, because the side passage is narrow and shared with a neighbour's wall. It is worth settling that before choosing equipment.
In short
- Glazing and orientation move the load more than floor area.
- An oversized unit dehumidifies badly and cycles itself to an early death.
- Place the indoor unit so air travels along the ceiling, not onto the bed.